A series-parallel (combination) circuit combines series elements and parallel banks within the same network. To the DC power supply, the entire combination network still appears as a single total resistance (RT). Solving or troubleshooting any series-parallel circuit requires applying series rules to the series sections and parallel rules to the parallel sections in a strict six-step order of operations.
1. The Mandatory 6-Step Reduction & Solution Process
Step-by-Step Order of Operations (ELO 28XX-MAIN-1002ba)
Step
Action
Governing Rule & Formula
Step 1
Work Out All Parallel Sections (REQ)
Reduce every parallel bank to a single Equivalent Resistance (REQ) using the Reciprocal (RSOR), Product-Over-Sum (R2+R3R2×R3), or Value-Over-Number (NR) method.
Step 2
Redraw the Circuit & Solve for Total Resistance (RT)
Redraw the schematic as a simple series circuit with REQ replacing the parallel bank, then add all series resistances together:
RT=R1+REQ
Step 3
Find Total Current (IT)
Using total resistance (RT) and applied voltage (VA), calculate total circuit current via Ohm’s Law:
IT=RTVA
Because R1 and the parallel bank (REQ) are in series with the source, IR1=IREQ=IT.
Step 4
Solve for Series Voltage Drops (VR1,VREQ)
Using common series current (IT), calculate the voltage drop across each series element and across the equivalent parallel bank:
VR1=IT×R1andVREQ=IT×REQ
(Verify with KVL: VA=VR1+VREQ.)
Step 5
Solve for Parallel Branch Currents (IR2,IR3)
Expand REQ back into its parallel branches. Because voltage is common in parallel, the voltage across every branch in that bank equals VREQ (VR2=VR3=VREQ). Calculate each branch current:
IR2=R2VREQandIR3=R3VREQ
(Verify with KCL: IR2+IR3=IT.)
Step 6
Solve for Individual & Total Power (P)
Calculate power for each resistor (Px=Ix×Vx) and verify that the sum of all individual resistor powers equals total circuit power:
PT=PR1+PR2+PR3=IT×VA
2. Loaded Voltage Dividers & The 10:1 Rule
When an external device or circuit (Load, RL) is connected to tap a specific voltage off a series voltage divider, RL is wired in parallel with one of the voltage divider’s resistors (R2), transforming the circuit into a series-parallel loaded voltage divider.
Key Loaded Voltage Divider Concepts
The Load (RL): Represents the external component or subsystem being powered by the voltage divider (absorbs power to perform work).
The Loading Effect: Connecting RL in parallel with R2 creates a parallel bank whose equivalent resistance (REQ=R2∥RL) is always smaller than R2 alone.
Because REQ decreases, total circuit resistance (RT=R1+REQ) decreases, total current (IT) increases, the voltage drop across series resistor R1 (VR1=IT×R1) increases, and the output voltage across the load (VL / Vout) DECREASES (“droops”).
Proportionality Summary:
Smaller RL⟹Smaller REQ⟹Smaller Output Voltage (VL)⟹Larger Load Current (IL)
The 10:1 Loading Rule: To prevent unacceptable output voltage loss when the load is connected, a voltage divider is designed so that the load resistance (RL) is at least 10 times greater than the bleeder resistor (R2) (RL≥10×R2).
Example: If R1=2kΩ and R2=4kΩ, choosing RL≥40kΩ keeps REQ (4kΩ∥40kΩ=3.64kΩ) close to 4kΩ, minimizing voltage droop.
Load Current (IL) vs. Bleeder Current (IR2):
Load Current (IL): Current flowing through the load device (RL).
Bleeder Current (IR2): Current flowing through the divider resistor (R2) in the branch parallel to the load.
3. Worked Circuit & Fault Demonstrations
Demonstration 1: Complete 6-Step Calculation
Given:VA=15V, series resistor R1=1kΩ, and parallel branches R2=2kΩ∥R3=3kΩ.